Actifoam Firestops |
Firestop with Actifoam withstands three-hour fire test
A new version of the FIRSTO firestop with Actifoam fire resistant
foam rubber has successfully withstood a fire test lasting three
hours. The test, which was carried out by Underwriter’s Laboratories
(Northbrook, USA), demonstrates that Beele Engineering’s
Actifoam firestop continues to function under the severest possible
fire load. Even when the firestop with Actifoam is positioned completely
on the exposed side, no smoke emission occurs at the unexposed
side during the first hour of the test.
The certification for three hours fire resistance is valid for
installations where the FIRSTO firestop is installed at the upper
side of a floor or at both sides of a wall. When the firestop system
is installed at the underside of a floor or at one side of a wall,
the certificated fire resistance is two hours.
In addition to their capacity to prevent the spread of fire and
smoke, FIRSTO firestops are also capable of withstanding mechanical
loads. The metal firestops are of modular construction, and are
assembled in a simple way around the cable tray against the wall
or on the floor. An important advantage of this firestop is the
ease with which it enables cables to be added or removed at a later
date.
In addition to their capacity to prevent the spread of
fire and smoke, FIRSTO firestops are also capable of withstanding
mechanical loads. The metal firestops are of modular construction,
and are assembled in a simple way around the cable tray against
the wall or on the floor. An important advantage of this
firestop is the ease with which it enables cables to be added
or removed at a later date.
The metal FIRSTO casing consists of a housing, attachment
brackets and a cover, which are fitted against the wall
or on the floor. A fire resistant packing is applied between
the casing and the wall or the floor. Inside the casing,
inserts made of the fire resistant and thermally insulating
Actifoam foam rubber are placed all around against the
walls
and under the cover. The space around the cable tray and
between the cables is filled up with Actifoam inserts and
with Actifoam separation profiles respectively.
FIRSTO firestops are supplied fully assembled, which simplifies
materials management and minimizes the risk of components
going astray. |
|

A
new version of Beele Engineering’s FIRSTO firestop with
Actifoam fire resistant foam rubber has successfully withstood
a three hour fire test by Underwriter’s Laboratories. |
Actifoam is used among other things for the purpose of filling
openings in constructions. In the case of an outbreak of fire,
the openings will be completely closed off by the expanding rubber.
Due to its closed cell structure, volume expansion will occur
only at the seat of the fire. This non-intumescent process ensures
that the expansion is not accompanied by any large-scale smoke
formation. As a result of its closed cell structure, Actifoam
moreover possesses good thermal insulation properties. Actifoam
will not absorb any moisture and has been tested for 24 hours
at 2.5 bar water pressure.
FIRSTO and Actifoam have been developed by Beele Engineering
of Aalten*) and are marketed in the United States by CSD Sealing
Systems of Melrose, Mass.
Actifoam Fire Behavior.pdf (requires: Adobe
Acrobat)
For additional information about Actifoam, please contact
us.
*) Beunkdijk 11, 7122 NZ Aalten, the Netherlands, tel. +31 543
461629, fax +31 543 461786
E-mail: info@beele.com, website: www.rise-systems.com
|